Chengdu Ample Import And Export Co., Ltd.

One-Stop Solutions of Fume Hood, Biosafety Cabinet, Laboratory Furniture

Manufacturer from China
Active Member
4 Years
Home /

Chengdu Ample Import And Export Co., Ltd.

Product Categories
Contact Now
Chengdu Ample Import And Export Co., Ltd.
City:chengdu
Country/Region:china
Contact Person:MrMike Ma
Contact Now

Chengdu Ample Import And Export Co., Ltd.

Images
3
China Chengdu Ample Import And Export Co., Ltd. manufacturer
China Chengdu Ample Import And Export Co., Ltd. manufacturer
China Chengdu Ample Import And Export Co., Ltd. manufacturer
Company Profile

Chengdu Ample Import and Export Co., Ltd. is a professional solution-oriented supplier aiming to be one of the leading Exporter and Manufacturer of Laboratory furniture such as lab fume hoods, lab storage cabinets, and benches, Office chairs, with well-equipped testing facilities and strong technical force.

Our products are extensively used in many industry fields with a wide range, good quality, reasonable prices, and advanced designs.

One of the Ample factories specializes in laboratory protective products to meet the requirements of different kinds of laboratory experiments. We also supply customers with China's Top-quality medical devices at the factory-direct price.

We both provide customized products and OEM service for our all products.

Our company tenet is Top in Quality, Best in Service.

Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs.

We sincerely welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!

China Chengdu Ample Import And Export Co., Ltd. manufacturer

Company Information
Basic Information
Company Name: Chengdu Ample Import And Export Co., Ltd.
Business Type: Manufacturer,Exporter,Trading Company
Brands: Ample
Employee Number: 50~100
Year Established: 2019
Total Sales Annual: 500000-2000000
Company Location: T2-715, Landmark Plaza, High-Tech Zone, Chengdu, China
Factory Location: Shatou Park, Logistics Industrial Park, Jiujiang Town, Nanhai District, Foshan, Guangdong, China
Trade & Market
  • Company slogan:

    One-Stop Solutions of Fume Hood, Biosafety Cabinet, Laboratory Furniture

  • OEM Overview:

    We provide kinds of fume hood for your choices

    • Distillation Fume Hood

    A distillation hood is characterized by a low worktop height which results in a large working height for the operator. This allows tall distillation equipment to be installed and mounted in the work chamber. Otherwise, it has similar features to that of a standard fume hood.

     

    • Perchloric Acid Fume Hood

    Perchloric acid reacts violently with organic materials. Dried perchloric acid is also highly explosive. Therefore, perchloric fume hoods require built-in water wash down systems in order to prevent perchlorate salt deposits. Interior liners are made of acid resistant materials like stainless steel. Interior corners are coved to aid in cleaning. All procedures that use perchloric acid must be confined to a perchloric fume hood, to prevent dangerous reactions with other chemicals.

     

    China Chengdu Ample Import And Export Co., Ltd. manufacturer• Radioisotope Fume Hood

    Radioisotope fume hoods are constructed specifically to protect users from radioactive materials. They have specially constructed worktops to withstand the weight of lead shielding plates, and may also have lead laced sashes. Interiors are made of stainless steel with coved corners to aid in decontamination.

     

    • Acid Digestion Fume Hood

    Acid digestion fume hoods have special liners manufactured of acid resistant materials such as unplasticized PVC. For acid digestion applications involving high service temperatures, other materials such as PVDF may be used. Sashes may be made of polycarbonate to resist hydrofluoric acid etching.

     

    • Floor Mounted Fume Hood

    Floor mounted fume hoods are used for applications which require large apparatus. As the name implies, these hoods are floor mounted without any work surface. This facilitates the transfer of equipment and materials into, and out from the hood. Floor mounted hoods are sometimes referred to, although wrongly, as walk-in fume hoods.

     

    • Demonstration Fume Hood

    A demonstration hood has all 4 sides made of safety glass, and this hood is commonly used in educational institutions to allow students to easily view the teachers’ demonstrations inside the fume hood from all angles, enhancing efficiency in teaching laboratories.

     

    • Ductless Fume Hood

    Ductless fume hoods utilize activated carbon filtration to adsorb chemical vapors and fumes. These hoods recirculate air to the laboratory, and are growing in popularity because of energy savings and the green movement.

     

  • Production Line:

    Laboratory fume hoods are a type of ventilation system with the primary function to exhaust chemical fumes, vapors, gasses, dust, mist and aerosol. Fume hoods also serve as physical barriers between reactions and the laboratory, offering a measure of protection against inhalation exposure, chemical spills, run-away reactions and fires.

    A typical fume hood has a box like structure with a moveable sash window. Experimental procedures are performed within the hood which is consistently and safely ventilated, usually by means of an extract blower and ductwork. Chemical fumes are exhausted and diluted many times over in the atmosphere and have a negligible effect on human health. When environment concerns are of importance, an extract treatment system, often referred to as a scrubber is installed to remove most of the vapors from the exhaust air stream.

  • R&D:

    Fume hoods should be suitably sited to ensure maximum containment. Locate hoods to avoid crosscurrents at the hood face due to pedestrian traffic, doors and supply air diffusers. Sufficient laboratory supply air must be available to allow hoods to operate at their specified face velocities.

    A fume hood is not designed to contain high velocity releases of particulate contaminants unless the sash is fully closed. The hood is not capable of containing explosions, even when the sash is fully closed. If an explosion hazard exists, the user should provide anchored barriers, shields or enclosures of sufficient strength to deflect or contain it. Such barriers can significantly affect the airflow in the hood.

    A conventional fume hood must not be used for perchloric acid. Perchloric acid vapors can settle on ductwork, resulting in the deposition of perchlorate crystals. Perchlorates can accumulate on surfaces and have been known to detonate on contact, causing serious injury to researchers and maintenance personnel. Specialized perchloric acid hoods, made of stainless steel and equipped with a wash down system must be used for such work.

  • Our Team:

    Building a successful team is about more than finding a group of people with the right mix of professional skills.

  • History:

    Labs are a risky environment. Between the sharp objects and beakers lined up in rows, workers have to constantly be aware of their surroundings. Personal protective equipment and other controls are part of what keep them safe, and fume hoods are no exception.

    Fume hoods are an engineering control in labs, meaning they control the hazard. When scientists are working with dangerous materials that emit hazardous vapors, gas, and dust, a fume hood will move it away from their faces and out of the area through an exhaust system.

    Without getting too deep into the weeds about the inner workings of the mechanism, it’s essential that they are always in working order. Professionals should thoroughly inspect and document fume hoods on an annual basis. A quick visual inspection should be done every time it’s used. If there is any suspicion that a fume hood is not working correctly, it’s imperative to get in touch with someone ASAP.

  • Service:

     Polypropylene Fume Hoods are excellent chemical resistant laboratory safety hood designed for high corrosive applications such as acid handling and they are protecting laboratory workers when working with toxic chemicals, vapors, gases, dusts, flammable and hazardous materials.

     

    The chemical fume hoods are total exhaust system require ductwork. They are available with and without bottom work surface and in variety of sizes from 24” to 96” length. The single walled construction provides maximum work space. External lighting make it explosion & spark proof unless it equipped with blower module. (Blower is optional, is not explosion proof nor rated for acid and corrosive chemicals).

     

    The fume hood is an important piece of laboratory safety equipment designed to protect personnel and the environment from toxic fumes by drawing air from a contained area. The lining material of a fume hood confers its containment properties and polypropylene offers many advantages in this regard.

     

    When purchasing a polypropylene fume hood, some factors to consider include the size of the hood—most common sizes run from 3-8 feet, whether your lab has ducting capabilities or if a ductless model is needed, whether a constant volume or variable air volume exhaust system will be used, the material and operating speed of the blower, sash height, and the benchtop material. After purchase, fume hoods require regular maintenance and adherence to safety guidelines; always be sure to follow manufacturer instructions to ensure maximum safety.

     